More than 150 countries customers enjoy the service of kulon

OWA-60U

OWA-60U
CategoriesUSA 2 Pin
AlbumView larger image
BrandMeanwell Switching Power Supply
ModelOWA-60U
Wattage60W
Input90 ~ 264VAC
Output(VDC)12,15,20,24,30,36,42,48,54
PFC-
SafetyUL FCC
L*W*H130*53*35mm
Warranty5 Years
Update Time2021-04-18
Detail Information

60W Single Output Moistureproof Adaptor OWA-60U series

  • Ultra AC input / Full range(up to 264VAC0)

  • High efficiency up to 91%

  • Protections:Short circuit / Over current / Over voltage / Over temperature

  • Class II power unit no FG

  • Class 2 power unit

  • Fully isolated plastic case

  • Fanless design cooling by free air convection

  • No load power consumption<0.15w

  • Comply with EISA 2007 DOE and NRCan

  • UL LISTED suitable for dry and damp locations

  • 5 year warranty

specification:

MODEL OWA-60U-12 OWA-60U-15 OWA-60U-20 OWA-60U-24 OWA-60U-30 OWA-60U-36 OWA-60U-42 OWA-60U-48 OWA-60U-54
OUTPUT DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V
CONSTANT CURRENT REGION 6 ~ 12V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V
RATED CURRENT 5A 4A 3A 2.5A 2A 1.67A 1.5A 1.25A 1.12A
RATED POWER 60W 60W 60W 60W 60W 60.12W 63W 60W 60.48W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p
VOLTAGE TOLERANCE Note.3 ±4.0% ±4.0% ±4.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATION ±1.5% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME Note.4 500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load
HOLD UP TIME (Typ.) 10ms at full load 115VAC / 230VAC
INPUT VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 87% 88% 88% 88.5% 88.5% 88.5% 88.5% 88.5% 89%
88% 89% 89% 90% 90% 90% 90% 91% 91%
AC CURRENT (Typ.) 1.2A/ 115VAC 0.7A/ 230VAC
INRUSH CURRENT (Typ.) COLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VAC
COLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.25mA/ 240VAC
First row is a table header
Review
  • Loading...
Related Products
Get in Touch

Quick Service & Solution For Full Meanwell Products

If you have any questions about purchasing Meanwell products, any doubts in product selection, or any special needs for Meanwell products, welcome contact us as follows:

Stay in touch
Please send your message to us
*Email
*Name
*Tel
*Title
*Content

Agree to use terms of service