More than 150 countries customers enjoy the service of kulon

GSM40B

GSM40B
CategoriesClass II
BrandMeanwell Switching Power Supply
ModelGSM40B
Wattage40W
Input80〜264VAC
Output(VDC)5,7.5,9,12,15,18~20,24,48
PFC-
SafetyCUL,TUV,CB,CE,FC,EAC
L*W*H125*50*31.5mm(L*W*H)
Warranty3 Years
Update Time2021-06-13
Detail Information

40WAC-DC High Reliability MedicalAdaptor GSM40B series

  • 2 pole AC inlet IEC320-C8 Class II power unit

  • Medical safety approved (2xMOPP ) accroding to ANSI/AAMI ES60601-1 and IEC/EN60601-1

  • Extremely low leakage current

  • No load power consuption<0.1w 

  • Energy efficiency level vi and meet COC version 5 (except 5~9V for Level V)

  • Comply with Korea K-MEPS(only GSM40B48-P1J 

  • -30+70C wide range working temperature

  • Protections:Short circit / Overload / Over voltage

  • LED indicator for power on

  • Lifetime>90K hours

  • 3 year warranty

specification:

MODEL GSM40B05-P1J GSM40B07-P1J GSM40B09-P1J GSM40B12-P1J GSM40B15-P1J GSM40B18-P1J GSM40B24-P1J GSM40B48-P1J
OUTPUT SAFETY MODEL NO. GSM40B05 GSM40B07 GSM40B09 GSM40B12 GSM40B15 GSM40B18 GSM40B24 GSM40B48
DC VOLTAGE Note.2 5V 7.5V 9V 12V 15V 18V 24V 48V
RATED CURRENT 5A 5.34A 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A
CURRENT RANGE 0 ~ 5A 0 ~ 5.34A 0 ~ 4.45A 0 ~ 3.34A 0 ~ 2.67A 0 ~ 2.22A 0 ~ 1.67A 0 ~ 0.84A
RATED POWER (max.) 25W 40W 40W 40W 40W 40W 40W 40W
RIPPLE & NOISE (max.) Note.3 80mVp-p 80mVp-p 100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5%
LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATION Note.6 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5%
SETUP, RISE, HOLD UP TIME 1000ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.) 50ms / 230VAC 24ms / 115VAC at full load
INPUT VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
   
EFFICIENCY (Typ.) 81% 85.5% 86% 88% 88.5% 89% 90% 91%
AC CURRENT (Typ.) 1A/ 115VAC 0.5A/ 230VAC
INRUSH CURRENT (max.)  Cold start 30A/ 115VAC 60A/ 230VAC
LEAKAGE CURRENT(max.) Touch current < 50 A/264VAC
First row is a table header
Other
Review
  • Loading...
Get in Touch

Quick Service & Solution For Full Meanwell Products

If you have any questions about purchasing Meanwell products, any doubts in product selection, or any special needs for Meanwell products, welcome contact us as follows:

Stay in touch
Please send your message to us
*Email
*Name
*Tel
*Title
*Content

Agree to use terms of service