More than 150 countries customers enjoy the service of kulon

Home > Products > G3 Series > Quad >

RQ-125

RQ-125

RQ-125
CategoriesQuad
AlbumView larger image
BrandMeanwell Switching Power Supply
ModelRQ-125
Wattage125w
Input85-264VAC
Output(Vdc)5v 12v -5v -12v,5v 15v -5v -15v,5v 12v 24v -12v,
PFC-
SafetyUL,TUV,CB,CE,EMC
L*W*H199*98*38mm (L*W*H)
Warranty3 years
Update Time2021-04-18
Detail Information

125W Quad Output Switching Power Supply RQ-125 series

Feature:

  • Protections: Short circuit / Overload / Over voltage 

  • Cooling by free air convection 

  • LED indicator for power on

  • 100% full load burn-in test

  • All using 105   long life electrolytic capacitors°C

  • Withstand 300VAC surge input for 5 second

  • High operating temperature up to 70°C

  • Withstand 5G vibration test

  • High efficiency, long life and high reliability

  • 3 years warranty

specification:

MODEL RQ-125B RQ-125C RQ-125D
OUTPUT OUTPUT NUMBER CH1 CH2 CH3 CH4 CH2 CH3 CH1 CH4 CH3 CH1 CH2 CH4
DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V
RATED CURRENT 11A 4.5A 1A 0.5A 10A 4A 1A 0.5A 8A 2.5A 2A 0.5A
CURRENT RANGE 2 ~ 12A 0.5 ~ 4.5A 0.1 ~ 1A 0 ~ 1A 2 ~ 12A 0.5 ~ 4A 0.1 ~ 1A 0 ~ 1A 2 ~ 12A 0.5 ~ 4A 0.1 ~ 2.5A 0 ~ 1A
RATED POWER 120W 122.5W 124W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 150mVp-p 80mVp-p
VOLTAGEADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±8.-3% ±6.-10% ±5.0% ±2.0% ±8.-3% ±6.-10% ±5.0% ±2.0% ±8.-3% ±8.0% ±5.0%
LINE REGULATION Note.4 ±0.5% ±1.0% ±1.0% ±1.0% ±0.5% ±1.0% ±1.0% ±1.0% ±0.5% ±1.0% ±1.0% ±1.0%
LOAD REGULATION Note.5 ±1.0% ±3.0% ±6.0% ±2.0% ±1.0% ±3.0% ±6.0% ±2.0% ±1.0% ±3.0% ±5..0% ±2.0%
SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 25ms/230VAC30ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 79% 80% 82%
AC CURRENT (Typ.) 3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA/ 240VAC
Other
Review
  • Loading...
Related Products
Get in Touch

Quick Service & Solution For Full Meanwell Products

If you have any questions about purchasing Meanwell products, any doubts in product selection, or any special needs for Meanwell products, welcome contact us as follows:

Stay in touch
Please send your message to us
*Email
*Name
*Tel
*Title
*Content

Agree to use terms of service